The High Current Rectifiers listed on this website is customized, just for your reference. If you have any specific demands,please tell us the parameters in details. We’ll be more than happy to work with you to meet your exact requirements.


1  A.C. INPUT

• A.C: rated voltage

• Phases

• Frequency

2  D.C. OUTPUT

• Rated D.C. voltage

• Rated D.C. current

• D.C. voltage fine control range (thyristors)

• D.C: current control range

• Accuracy of current fine control

• Pulse number

• Ripple

 

Structure overview:

The control cabinet is of GGD closed structure and opposed access door at the front and back for operation and maintenance. The gauge, control switch and potentiometer are installed front door plank of the cabinet; the signal light is installed on the top panel in the front of the cabinet and the entrance hole is set at the bottom of the cabinet for user connection. See Figure (II) for its appearance and installation dimensions.

Model

KHS-40000A/190V

Efficiency

≥98.8%

Input Voltage

AC10KV

Rated Voltage

DC190V

Input Current

AC728A

Rated Current

DC40000A

Range of Regulation

 

On-load Voltage Regulation+ Thyristor Phase Controlled Voltage Regulation: 0%-100% Udn

Notes forOrder

 

Input Voltage

AC380V-330KV

Optional


Frequency

40-60Hz

Optional


Current Regalation


Optional


Voltage Regulation


Optional


Rated Current


Optional


Rated Voltage


Optional


Cooling Mothed

Water,Air,natural or Forced

Draft Cooling

Optional

Digest of High Current Rectifier(HCR)technical documents.

Part eight of User Manual


Chapter II: Instructions for Use of Control Cabinet

I. Purpose:

ZK-KS control cabinet, characterized by good output characteristics, simple structure, reliable performance, strong anti-interference performance and convenient regulation and maintenance, applies to trigger control and protection of the silicon controlled rectifier used as electrolytic power supply.

II. Product standards and service conditions:

1. The product meets the following standards:

IEC146 International Electrotechnical Commission Standard

GB3859-93 Power Semiconductor Converters

JB/T7840-1998 and other standard requirements

2.1 The AC network shall meet the provisions in 4.1.1 of GB3859-93.

2.2 The altitude does not exceed 1000m.

2.3 The indoor and environment temperature is 5℃~+40℃, with the change no more than 30℃ within 24h.

2.4 The relative humidity does not exceed 90%.

2.5 There is no conductive, explosive dust or gas or steam corroding metal or destroying insulation in the operation site.

2.6 There is no violent vibration or impact and the vertical gradient during installation does not exceed 5%.

3. Main technical performance:

3.1 Working system: system II 100%Idn continuous

3.2 Cooling mode: natural cooling

3.3 Voltage regulating range: 0-100% rated voltage

3.4 Steady current precision: ±0.5

III. Structure overview and working principle

1. Structure overview:

The control cabinet is of GGD closed structure and opposed access door at the front and back for operation and maintenance. The gauge, control switch and potentiometer are installed front door plank of the cabinet; the signal light is installed on the top panel in the front of the cabinet and the entrance hole is set at the bottom of the cabinet for user connection. See Figure (II) for its appearance and installation dimensions.

2. Electrical principle and description

The control loop of the control cabinet contains the fault signal detection circuit and trigger control circuit. The fault signal detection circuit mainly contains the corollary equipment failure and state quantity collection, DC current and DC voltage collection, rectifier transformer oil temperature and rectifier cooling water temperature and pressure collection. The trigger control circuit contains feedback signal disconnection and other protection functions. The running program is logic and has fault self-diagnosis alarm and handling system. For higher system operation reliability, the control system also has the zero start function. The control system of the device has two forms, as follows:

2.1 Fault signal detection circuit

Siemens programmable logic controller PLC is mainly used to achieve good collection and logic processing and the LCD touch screen is used to achieve detection and control.

2.2 Trigger control circuit

       Two channels are established for simultaneous working, one for system hot standby and the other for system working. In case of failure in the running channel, the online standby system is quickly and automatically converted to operation, effectively ensuring normal operation of the system. To achieve maximum power factor of the system and reduce the harmonic quantity, the control system is equipped with the combined operation system of α control angle and on-load switch. According to different load needs of the user, the programmable control system is used for program control, further improving the overall stability and reliability of equipment.

See Chapter III and V.




High Current Rectifier(HRC)KHS-40000A/190V Structure Feature & Advantages

▲ Adopted cophase counter parallel connection Rectification,wihich can increase the power factor and reduce power loss

▲ Three-phase bridge rectification,which has the characteristics of reliability,stability,and low losses

▲ Adopted aluminum frame and glass antimagnetic cabinet, which suit for monitor and maintenance

▲ Power is scalable

▲ Can be maintained with electricity.

▲ With Low noise 

▲ Easy to operate 

▲ Superiority of Ture Rdundancy technique

▲Over / low Voltage protection    

▲Over / low current protection   

▲Over / lack water protection        

▲Over temperature protection

▲Fast fuse protection      

▲Phase protection  

 

Our products of High Current Rectifier (HRC) are customized according to clients’s parameters.They are used in variety of applications as follows:

1.Plating: Chrome, Zine, Nickel, Copper, Gold, Silver

2.Metal smelting: Aluminum, Copper,  Zine, Lead, Manganese, Magnesium, etc.

3.Ionic membrane: Electrolysis of salt, etc

4.Silicon carbide smelting & Graphitization furnace

5.Experimental power supply

6.Copper foil, aluminum foil special power supply

7.Electrochemical: Chlor-alkali, etc

8.Electrolysis: Copper, Zine, Tin, Lead, Aluminum foil, Copper foil

 

The expert teams with 20 years experience can supply equipment design,manufacture, upgrading and after sales service. It’s quality management system meets the requirement of the ISO9001:2008 standard. The Technical level of main equpment is ten years ahead in China,and the control system is twenty years ahead at home and abroad.

We service with pride and care and give you a best solution.

 

1. Within the first year, if you need any spare parts for replacement, we can provide to you without

paid. And we will offer lifelong technical support and service.

 

2. Within the first year, if you need any spare parts for replacement, we can provide to you without

paid. And we will offer lifelong technical support and service.

 

1.Q:Are you a factory or trading company? 

A: We are a factory.

 

2. Q: Where is your factory? How can I visit there?

A: Our factory is located in Xi’an, middle part of China, about an hour bus ride from Xi’an Xianyang Airport, which in the starting point of Ancient Silk Road.Welcome to visit us.

 

3. Q:When can I get the price?

A:Usually we quote within 24 hours after we get your inquiry.


Total0bar [View All]  Related Comments
 
more»Other products

[ Products search ] [ favorites ] [ Tell friends ] [ Print ] [ Close ]